45530A
08-02-2012
Printed in Canada
Installation and Operation Manual
FP-7-LM
ANTOINETTE
Qualified Clean Burning
Decorative Fireplace
U.S. EPA Low Mass Wood-burning Fireplace
voluntary program phase 2 emission level qualified model
Safety tested according to ULC S610 and
UL 127 Standards by
Stove Builder International Inc.
250, rue de Copenhague,
St-Augustin-de-Desmoures (Quebec)
Canada G3A 2H3
Tel : (418 ) 878-3040
Fax : (418 ) 878-3001
www.valcourtinc.com
READ AND KEEP THIS MANUAL FOR REFERENCE
This manual is available for free download on the manufacturer’s web site. It is a copyrighted
document. Re-sale is strictly prohibited. The manufacturer may update this manual from time
to time and cannot be responsible for problems, injuries, or damages arising out of the use of
information contained in any manual obtained from unauthorized sources.
Page view 0
1 2 3 4 5 6 ... 55 56

Summary of Contents

Page 1 - ANTOINETTE

45530A 08-02-2012 Printed in Canada Installation and Operation Manual FP-7-LM ANTOINETTE Qualified Clean Burn

Page 2

10 3. As illustrated in Figure 6 and 7, position the heat shield (C) between the spacers previously installed with the folds facing up. Align the h

Page 3

11 Figure 3.3 A Figure 3.3 B Figure 3.3 C Figure 3.3 D Figure 3.3 E Figure 3.3 F Figure 3.3 G D E

Page 4

12 3.4 Locating the FP7-LM Antoinette Wood Fireplace A. The best location to install your fireplace is determined by considering the location of wind

Page 5 - PART A – INSTALLATION

13 Figure 8 Installation on raised base Figure 9 Ceiling clearance requirements 3.5 Heart Extension Requirements The hearth extension floor

Page 6 - 2.0 General Information

14 Figure 10 Figure 11 3.6 Framing, Facing, Mantel, and Combustible Shelf 3.6.1 Framing The construction of the framing, facing, and mantel

Page 7

15 B. Frame the fireplace with vertical studs on each side of the fireplace running from floor to ceiling (see Figure 15). Position the studs back fr

Page 9 - Figure 4

17 Figure 15

Page 10

18 Figure 16

Page 11

19 Figure 17 Insulated chase construction

Page 12

2 THANK YOU FOR CHOOSING THIS VALCOURT FIREPLACE As one of North America’s largest and most respected wood stove and fireplace manufacturers, VALCO

Page 13

20 Figure 18 Spacers must be installed

Page 14

21 3.6.2 Facing CAUTION: BEFORE CLOSING THE WALLS, MAKE SURE THAT THE AIR CONTROL MECHANISM, THE FLUE DAMPER AND DOORS MECHANISM WORK PROPERLY. A

Page 15

22 Facing With the Narrow Overlap Figure 19

Page 16

23 Facing With the Masonry Trim Figure 20

Page 17

24 Figure 21 CAUTION: DO NOT SCREW IN THE HACHURED ZONE (See Figure 21) 3.6.3 Combustible Shelf To install any combustible shelf, refer to Fig

Page 18

25 SHELFPOSITIONINGSHELFDIMENSION SHELFPOSITION6"/152mm 46"/1168mm8"/203mm 48"/1219mm10"/254mm 5

Page 20 - Figure 18

27 3.7 Fresh Air Kit During operation, the fireplace requires fresh air for combustion and draws air out of the house. It may starve other fuel bur

Page 21

28 Figure 24 Figure 25

Page 22

29 Perform an opening in the exterior wall according to the size of the wall termination. From outside, place the outside air inlet cap in the hole (

Page 23

3 PART A – INSTALLATION ... 51.0 Safety Information ...

Page 24

30 Figure 27 Narrow Overlap 3.8.2 Masonry Trim WARNING: THE PLATING OF THE MASONRY TRIM SHOULD NEVER COME IN CONTACT WITH MASONRY PRODUCT SUCH

Page 25 - SHELFPOSITIONING

31 1. Once the fireplace is fully installed, press the masonry trim (A) against the fireplace (the longest side towards the bottom going inside the

Page 26

32 To adjust screen door 1. Lift the screen and the glass door completely to the top. 2. Unscrew one of the two bolts (A) which are located on the lo

Page 27 - 3.7 Fresh Air Kit

33 4.2 Suitable Chimneys This wood fireplace may be connected to either a factory-built metal or a masonry chimney. Whether metal or masonry, the chi

Page 28

34 WARNING: IF THE MALE NOZZLE "HATCHED AREA (A)" OF THE ANCHOR PLATE EXCEEDS 2" (51 MM) IN LENGTH (VALUE (X), SEE IMAGE BELLOW), IT

Page 29

35 TABLE 2 – LIST OF MANDATORY COMPONENTS CHIMNEY MANUFACTURER MANDATORY COMPONENTS TYPE/BRAND Selkirk  Ventilated roof flashing 2" Solid

Page 30

36 8. If the chimney extends higher than 5 ft. (1.5 m) above its point of contact with the roof, it must be secured using a roof brace. 9. A rain c

Page 31 - 3.9 Door Alignment

37 12. When you build a chase enclosure for chimney sections above the roof, the chimney must extend at least 3 ft. (92 cm) above the chase enclosure

Page 32 - 4.1 General

38 4.4 Chimney Installation Instructions 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass. Use a plumb bob to

Page 33 - 4.2 Suitable Chimneys

39 EXAMPLE OF TYPICAL CHIMNEY INSTALLATION Figure 33

Page 34

4 PART B - OPERATION AND MAINTENANCE ... 455.0 Fuel ...

Page 35

40 TABLE 3 – THE MINIMUM SYSTEM HEIGHT WHEN USING ELBOWS IS: Fireplace model FP7-LM ANTOINETTE WOOD FIREPLACE Chimney model All models listed in T

Page 36

41 Figure 34 Figure 35

Page 37

42 4.6 Angled Radiation Shield When passing through a combustible wall with the chimney at a 30 or 45 angle (30 or 45 in Canada and 30 only in

Page 38

43 4.7.2 Universal Offset Support This support is used to support the chimney above an offset. When the chimney offset is used to pass through a wal

Page 39

44 4.9 Installation Instructions for Masonry Application WARNING: BEFORE STARTING THE INSTALLATION, THE MASONRY CHIMNEY MUST BE INSPECTED BY A QUAL

Page 40 - WHEN USING ELBOWS IS:

45 PART B - OPERATION AND MAINTENANCE 5.0 Fuel The FP7-LM ANTOINETTE WOOD FIREPLACE is designed to work best when fuelled with seasoned cordwood. Us

Page 41

46 6.0 OPERATING THE FP7-LM ANTOINETTE WOOD FIREPLACE Inside the firebox of your unit, you will find the handle that allows you to open the glass d

Page 42 - 4.6 Angled Radiation Shield

47 WARNING: NEVER PUT CORDWOOD IN FRONT OF THE ANDIRONS. WARNING: THIS FIREPLACE HAS NOT BEEN TESTED WITH A GAS LOG LIGHTER. CAUTION: NEVER USE

Page 43

48 6.4 Air Intake Control and Exhaust Damper The air intake control (dilution air) and exhaust damper should be in the closed position when there h

Page 44

49 B. Negative pressure in the house As the fire burns, air goes up the chimney. This air must be replaced through leakage into the house or through

Page 45 - 5.0 Fuel

5 PART A – INSTALLATION 1.0 Safety Information CAUTION: THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE ALWAYS OVERRIDE

Page 46 - 6.2 Building a Fire

50 7.0 MAINTAINING YOUR FP7-LM ANTOINETTE WOOD FIREPLACE 7.1 Creosote – Formation and Need for Removal When wood is burned slowly without a flame,

Page 47 - 6.3 Maintaining the Fire

51 Figure 40.1 Figure 40.2 Figure 40.3 Figure 40.4 7.4 Dealing With a Chimney Fire Regular chimney maintenance and inspection can prev

Page 48 - Causes and Troubleshooting

52 7.5 Disposal of Ashes Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a

Page 49 - F. Poor chimney draft

53 Figure 42.1 Figure 42.2 Figure 42.3 Figure 42.4 Figure 42.5 WARNING: DO NOT USE MATERIALS OTHER THAN THOSE LISTED IN THE REPLACEMENT PART

Page 50 - 7.2 Chimney Maintenance

54 7.7 Glass Care – Replacement The glass used in the FP7-LM ANTOINETTE WOOD FIREPLACE is ceramic glass 5 mm thick having dimensions of: 30 3/4” x

Page 51

55 Figure 43 7.8 Glass Care – Cleaning The FP7-LM ANTOINETTE WOOD FIREPLACE is designed to keep the glass clean under normal operating conditions.

Page 52 - 7.5 Disposal of Ashes

56 VALCOURT LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This

Page 53

6 CAUTION: THIS HEATING UNIT MUST SERVE AS A SUPPLEMENTARY HEAT SOURCE. AN ALTERNATIVE HEAT SOURCE SHOULD BE AVAILABLE IN THE HOME IF NEEDED. THE MA

Page 54

7 2.2 The Benefits of EPA Voluntary Emission Program «Low Mass» Phase II In the past, most conventional masonry and low-mass, factory-built firepla

Page 55 - 7.8 Glass Care – Cleaning

8 3.0 Fireplace Installation ATTENTION: IN ORDER TO COMPLETE THE FIREPLACE INSTALLATION AND DEPENDING ON THE TYPE OF FINISHING MATERIAL USED, YOU

Page 56 - DESCRIPTION

9 3.2 Installation of Spacers and Heat Shield To complete the fireplace, spacers and heat shield must be secured to the top of the appliance. Thes